针对地铁车辆段/停车场频频出现的打火问题,基于实际打火典型案例,按回流系统有无异常的情况分别阐述了杂散电流打火的原因。深入分析了镟轮库、洗车库及轨道车库等非电化股道在车轮过钢轨绝缘节时发生打火的原因。针对段场回流系统提出了设置回流隔离区、库内应避免出现直接或间接接地点等优化建议。
Stray current causes frequent arcing problem in metro depot and stabling yard.Based on actual typical arcing problem cases,reasons for stray current arcing issue is expounded in conditions whether backfeeding system has abnormality or not.The reason why arcing problems occur when wheels pass insulated rail joint on track without overhead contact system such as lathe library,washing garage and track garage is analyzed in-depth.Targeting depot and yard backfeeding system,optimization advices such as setting up backfeeding separation area,avoiding direct or indirect ground points inside garage are proposed.
作者
王宝顺
WANG Baoshun(Tianjin Metro Company Co.,Ltd.,300222,Tianjin,China)
出处
《城市轨道交通研究》
北大核心
2020年第11期160-163,共4页
Urban Mass Transit
关键词
地铁
车辆段
停车场
杂散电流
回流系统
metro
vehicle depot
stabling yard
stray current
backfeeding system