期刊文献+

LNG转运站储罐日蒸发率设计探究 被引量:8

Exploration on design for daily boil-off rate of storage tanks in LNG transfer-terminal
下载PDF
导出
摘要 以国内某LNG转运站30000 m^3容积LNG储罐为例,介绍了最大日蒸发率设计时需考虑的因素,分析了不同日蒸发率下LNG储罐的保冷材料费用及其运行费用。当日蒸发率设计为0.08%/d时,储罐保冷材料费用约占储罐成本的5.2%,符合一般LNG储罐保冷材料成本占比。该研究可为30000~100000 m^3容积LNG储罐日蒸发率的设计提供参考。 The factors to be considered in the design of maximum daily boil-off rate were introduced, and the cold insulation materials and operation costs of LNG storage tank under different daily boil-off rates were analyzed by the example of a 30000 m^3 LNG storage tank in a domestic LNG transfer-terminal. When the design value of daily boil-off rate was 0.08 %/d, the cost of the cold insulation materials accounts for about 5.2% of the storage tank cost, which is in line with the proportion of the cold insulation materials cost for the general LNG storage tank. The research can provide a reference for the design of the daily boil-off rate of 30000-100000 m^3 LNG storage tanks.
作者 扬帆 张超 陈锐莹 范嘉堃 张博超 刘洋 YANG Fan;ZHANG Chao;CHEN Rui-ying;FAN Jia-kun;ZHANG Bo-chao;LIU Yang(CNOOC Gas&Power Group Co.,Ltd.,Beijing 100028,China)
出处 《天然气化工—C1化学与化工》 CAS CSCD 北大核心 2020年第5期103-105,共3页 Natural Gas Chemical Industry
关键词 LNG转运站 LNG储罐 日蒸发率 LNG transfer-terminal LNG storage tank daily boil-off rate