期刊文献+

双啮合弦线转子泵的设计及流量分析 被引量:6

Design and Flow Analysis of Double Meshing String Rotor Pump
下载PDF
导出
摘要 为了降低弦线转子泵的流量脉动率和提高转子的面积利用系数,提出具有两对转子的双啮合弦线转子泵。分析转子径距比对弦线转子泵脉动率和转子面积利用系数的影响;探究双啮合弦线转子泵流量脉动率与两对转子之间的差动角大小的关系,得出了当差动角α=π/(2z)时,双啮合弦线转子泵的脉动率为0;且此时通过增大转子径距比可提高转子面积利用系数,使转子面积利用系数由原来的24.5%提高到45.1%。研究结果表明:双啮合弦线转子泵具有转子面积利用系数高、无流量脉动的特点。 In order to reduce the flow pulsation rate of the string rotor pump and increase the area utilization coefficient of the rotor,a double meshing string rotor pump with two pairs of rotors was proposed.The influence of the rotor pitch ratio on the pulsation rate of the rotor pump and the rotor area utilization factor was analyzed,the relationship between the flow pulsation rate of the double meshing rotor pump and the differential angle between the two pairs of rotors was investigated.It is concluded that when the differential angleα=π/(2 z),the pulsation rate of the double meshing string rotor pump is 0;at this time,the rotor area ratio can be increased by increasing the rotor pitch ratio,so that the rotor area utilization factor is increased from 24.5%to 45.1%.The research results show that the double meshing string rotor pump has the characteristics of high rotor area utilization coefficient and no flow pulsation.
作者 乔永强 邹旻 李亮亮 任爽 孙定华 QIAO Yongqiang;ZOU Min;LI Liangliang;REN Shuang;SUN Dinghua(School of Mechanical Engineering,Changzhou University,Changzhou Jiangsu 213164,China;Jiangsu Key Laboratory of Green Process Equipment,Changzhou University,Changzhou Jiangsu 213164,China;Department of Engineering Vehicles,Changzhou Traffic Technician College,Changzhou Jiangsu 213147,China)
出处 《机床与液压》 北大核心 2020年第20期144-147,84,共5页 Machine Tool & Hydraulics
基金 国家自然科学基金资助项目(51075046)。
关键词 双啮合弦线转子泵 流量脉动率 差动角 转子径距比 转子面积利用系数 Double meshing string rotor pump Flow pulsation rate Differential angle Rotor pitch ratio Rotor area utilization factor
  • 相关文献

参考文献11

二级参考文献62

共引文献65

同被引文献52

引证文献6

二级引证文献4

相关作者