期刊文献+

热稳定薄弱断面搜索及限额制定的在线算法 被引量:5

Online Algorithm for Searching and Limit Setting of Thermal-stability Weak Section
下载PDF
导出
摘要 为解决离线断面及限额不能实时匹配系统运行方式的问题,针对热稳定断面构成元件搜索、限额制定提出了一套在线算法。采用直流法计算支路开断、有功元件跳闸、母线跳闸3类故障的潮流转移,提出了将母线跳闸转化为虚拟短线开断的方法,使潮流转移关系得以显性表达。归纳得出了3类故障潮流转移通用线性表达式,为制定断面限额奠定了基础。提出了基于“风险支路+威胁元件”构成法的热稳断面构成元件搜索方法,基于潮流转移通用表达式提出了风险加权的断面监控指标构造方法及断面限额制定方法。对于涉及并联支路的相近断面给出了合并方法,对并联支路构成的断面给出了监控指标的化简方法。为保证求解速度和计算精度,采用直流法搜索与交流法校验修正相结合的计算策略。应用于实际案例,搜索的断面将离线断面所反映的热稳风险全面覆盖,计算限额与离线限额的一致性较好,验证了方法的有效性;每一轮计算耗时约3.6 min,满足在线应用要求。 To solve the problem that offline section and its transmission limit can’t well match the system operation state,a set of algorithms are proposed for searching and limit setting of thermal stability section components.Transferring flow power of three types of faults,i.e.,branch breaking,active power component tripping and bus tripping are calculated by DC method,and a method of transforming bus tripping into breaking several virtual short lines is proposed to explicitly express the power flow transferring relationship.General linear expressions for three power flow transferring types are concluded,which lays a foundation for setting section limits.The thermal stability section searching method based on“branch line at risk+component under threat”construction is demonstrated.By using the general expressions of power flow transferring,a risk-weighted monitoring index construction method and a limit setting method for sections are proposed.The merging method is given for the similar sections consisting of parallel branches,and the simplification method for monitoring index is given for the sections composed of parallel branches.To ensure the solving speed and accuracy,the calculation strategy combining DC searching method with AC correction method is adopted.Based on an actual example,the searched sections by the proposed algorithm cover all the thermal stability risks of the offline sections.Furthermore,the consistency of section limits between caculation limit and the offline limit is proven,and thus the validity of the proposed algorithm is testified.A round of calculation takes about 3.6 minutes,which meets the requirements of online application.
作者 刘阳 鄢发齐 汪旸 夏添 董向明 陈文哲 张慕婕 LIU Yang;YAN Faqi;WANG Yang;XIA Tian;DONG Xiangming;CHEN Wenzhe;ZHANG Mujie(Central China Branch of State Grid Corporation of China,Wuhan 430077,China)
出处 《电力系统自动化》 EI CSCD 北大核心 2020年第21期156-164,共9页 Automation of Electric Power Systems
关键词 热稳定 断面搜索 断面限额制定 监控指标 在线计算 离线计算 thermal stability section searching limit setting of section monitor index online calculation offline calculation
  • 相关文献

参考文献14

二级参考文献151

共引文献213

同被引文献73

引证文献5

二级引证文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部