四极杆碰撞反应池-电感耦合等离子体质谱法测定粉条中的铝 被引量:1

Determination of aluminum element in starch noodles by inductively coupled plasma-mass spectrometry with quadruple collision cell technology
下载PDF
导出
摘要 目的建立四极杆碰撞反应池-电感耦合等离子体质谱法测定粉条中铝元素的检测方法。方法样品经微波消解后使用电感耦合等离子体质谱仪进行检测,使用内标元素45Sc消除基体干扰和信号漂移,碰撞反应池(KED模式)消除质谱干扰。结果铝元素校正曲线相关系数为0.999783,方法检出限为0.045mg/kg,相对标准偏差为0.79%,加标回收率为88.4%~96.1%,粉丝粉条中铝成分分析标准物质检测结果在认定值范围内。结论该方法灵敏度高、准确性高、精密度好,适用于粉条中铝元素含量的检测。 Objective To establish a method for the determination of aluminum in vermicelli by inductively coupled plasma mass spectrometry with quadruple collision reaction cell. Methods After microwave digestion, the sample was detected by inductively coupled plasma mass spectrometry. Matrix interference and signal drift were eliminated by the internal standard element 45 Sc. Mass spectrum interference was eliminated by the collision reaction cell(KED mode). Results The correlation coefficient of aluminum correction curve was 0.999783. The limit of detection of the method was 0.045 mg/kg, the relative standard deviation was 0.79%, and the recovery rates ranged from 88.4% to 96.1%. The certified reference material of aluminum in starch noodles was in the range of certified value. Conclusion This method has high sensitivity, high accuracy and good precision, and is suitable for the determination of aluminum element content in powder strips.
作者 田晖 TIAN Hui(Maanshan Centre for Food and Drug Control,Maanshan 243000,China)
出处 《食品安全质量检测学报》 CAS 2020年第19期7100-7105,共6页 Journal of Food Safety and Quality
关键词 四极杆碰撞反应池 电感耦合等离子体质谱法 粉条 quadruple collision cell technology inductively coupled plasma-mass spectrometry aluminium starch noodles
  • 相关文献

参考文献17

二级参考文献247

共引文献586

同被引文献11

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部