期刊文献+

铅酸蓄电池充放电的要求及其维护措施分析

The Requirements of Charge and Discharge of Lead-acid Batteries and the Analysis of Maintenance Measures
下载PDF
导出
摘要 电池是UPS、EPS、DC屏等系统的重要部件,在工业、交通、铁路(包括地铁)、银行、证券、军事和航空等领域都有广泛的应用,供电系统的安全性也由电池所决定。由于铅酸蓄电池的体积和质量非常小,耐高温,相对稳定的电压,环保安全,良好的导电性,以及价格低廉等优势,在工业上备受青睐。文章阐述了阀控式铅酸蓄电池对充放电的要求,对其充放电技术进行了分析,并对日常使用中的维护方法和措施进行了探讨。 Battery is an important part of UPS、EPS、DC screen and other systems.It is widely used in industry,transportation,railway(including subway),banking,securities,military and aviation,and the safety of power supply system is also determined by battery.Because the volume and quality of acid battery are very small,high temperature resistance,relatively stable voltage,environmental protection and safety,good electrical conductivity,and low price,it is favored in industry.This paper describes the requirements of valve-controlled lead-acid battery for charge and discharge,analyzes its charge and discharge technology,and discusses the maintenance methods and measures in daily use.
作者 魏绍明 孙林辉 夏仲华 陈衡 纪晖 Wei Shao-ming;Sun Lin-hui;Xia Zhong-hua;Chen Heng;Ji Hui
出处 《电力系统装备》 2020年第20期106-108,共3页 Electric Power System Equipment
关键词 铅酸电池 电池充放电 维修措施 lead acid battery battery charge and discharge maintenance measures