摘要
应用ANSYS软件对2/3匝线圈触头和马蹄铁型双极纵磁触头进行有限元仿真分析,并在F-30多维磁场测量平台上对这两种结构的触头进行磁场测量。仿真计算结果为:2/3匝线圈式触头的磁场强度为3.7~5.6 mT,磁场滞后时间为1.28~1.4 ms,马蹄型触头的磁场强度为0.7~11 mT,磁场滞后时间为0.49~0.73 ms。磁场测量平台检测结果为:2/3匝线圈式触头的磁场强度为2.7~4.7 mT,磁场滞后时间为1.15~1.35 ms,马蹄型触头的磁场强度为3.1~9.7 mT,磁场滞后时间为0.48~0.69 ms。由此可见,马蹄铁型触头与线圈式触头相比,具有磁场强度高、通流能力强、磁场滞后时间短的优点。另外,试验结果与仿真结果相差不大,对于真空灭弧室触头结构的设计及优化具有重要的指导意义。
The strength and delay-time of the magnetic field,generated by the 2/3-turn coil(Type-A) and horseshoe bipolar(Type-B) magnetic-contacts,in high voltage large current magnetic vacuum circuit breaker,was mathematically modeled,numerically simulated with ANSYS software and experimentally measured with the self-built test platform.The influence of the contact types on the strength/delay-time of magnetic field was investigated.The simulated results show that Type-B contact outperforms Type-A contact because of larger magnetic field strength,greater current carrying capacity and shorter delay-time.For example,the magnetic field strengths of Type-A/B are 3.7~5.6 mT/0.7~11 mT,respectively;and the delay-times of Type-A/B are 1.28~1.4 ms/0.49~0.73 ms,respectively.The simulated and measured results were found to be in good agreement.We suggest that the simulated results be of some technological interest in design of high voltage large current magnetic vacuum circuit breaker.
作者
齐大翠
李小钊
刘世柏
薛从军
亓春伟
Qi Dacui;Li Xiaozhao;Liu Shibo;Xue Congjun;Qi Chunwei(Pinggao Group Co.,Ud.,Pingdingshan 467000,China)
出处
《真空科学与技术学报》
EI
CAS
CSCD
北大核心
2020年第10期932-936,共5页
Chinese Journal of Vacuum Science and Technology
基金
国家电网公司科技项目(基于提升配电网开关设备质量的核心元件关键制造工艺技术研究)。
关键词
磁场强度
磁场滞后时间
仿真分析
磁场测试系统
Magnetic field intensity
Magnetic field lag time
Simulation analysis
Magnetic field testing system