摘要 穿墙套管是40.5 kV空气绝缘开关柜的核心元器件之一,其绝缘性能决定了开关柜的绝缘水平。文中通过对穿墙套管的多起典型事故原因进行深入分析研究,明确了套管在安装使用过程中的关键技术。针对套管在选型和安装使用过程中出现的典型事故原因,提出了相应的预防措施。 Wall bushing is one of the core components of 40.5 kV air-insulated switchgear,and its insulation perfor-mance determines the insulation level of the whole switchgear.In this paper,the key technologies of bushing installa-tion and use are clarified through in-depth analysis and research on the causes of many typical accidents of wall bush-ings.Corresponding preventive measures are proposed for the typical causes of accidents in the process of bushing se-lection and installation.
作者 冷兆云 陈平 张书浩 顾寅 缪金 李东 周鑫阳 LENG Zhaoyun;CHEN Ping;ZHANG Shuhao;GU Yin;MIAO Jin;LI Dong;ZHOU Xinyang(State Grid Wuxi Power Supply Company,Jiangsu Wuxi 214000,China;Xi’an XD Switchgear Electric Co.,Ltd.,Xi’an 710077,China)
出处 《高压电器》 CAS CSCD 北大核心 2020年第11期51-56,共6页 High Voltage Apparatus
关键词 穿墙套管 双屏蔽 选型 电场仿真 wall bushing double shielding selection electric field simulation