期刊文献+

双低CT扫描联合迭代重建在鼻骨骨折诊断中的应用 被引量:3

The Application Value of Double Low CT Scanning Technique Combined with Iterative Reconstruction in Nasal Bone Fracture
下载PDF
导出
摘要 目的:探讨低千伏、低毫安联合迭代重建技术在鼻骨骨折诊断中的应用价值。方法:将117例怀疑鼻骨骨折患者简单随机分为A、B组,11例排除骨折,106例鼻骨骨折患者,每组各53例。A组管电压120kV、管电流150mAs,B组管电压90kV、管电流75mAs。A组、B组行迭代重建,比较两组图像的噪声、SNR、CNR、图像质量的主观评分和辐射剂量(ED)。结果:A组、B组噪声、SNR、CNR和图像质量的主观评分差异均无统计学意义(P>0.05);A、B两组ED差异具有统计学意义(P<0.05)。结论:在不降低鼻骨骨折成像质量的情况下,迭代重建技术能降低鼻骨骨折多层螺旋CT成像辐射剂量。 Objective:To explore the application value of double low CT scanning technique combined with iterative reconstruction in nasal bone fracture.Methods:106 patients were randomly average divided into group A and B.Group A、B tube voltage 120 kV、90 kV,tube current 150 mAs、75 mAs.Group A and group B were given iterative recombination.Two groups were compared for noise,SNR,CNR and subjective evaluation score.Results:Compared with two groups of noise,SNR,CNR and subjective evaluation score.The differences were no statistical significance(P>0.05).The difference of ED between group A and group B has statistical significance.Conclusion:The iterative reconstruction technique can reduce the radiation dose of multi-slice spiral CT in nasal bone fracture without reducing the imaging quality of nasal bone fracture.
作者 彭广宇 廖焕元 刘金丰 PENG Guang-yu;LIAO Huan-yuan;LIU Jin-feng(Guangdong Provincial People’s Hospital Zhuhai Hospital(Zhuhai Golden Bay Center Hospital),Zhuhai 519040,Guangdong Province,P.R.C.)
出处 《中国数字医学》 2020年第10期125-127,共3页 China Digital Medicine
关键词 迭代重建 鼻骨骨折 低剂量 iterative reconstruction nasal bone fracture low dose
  • 相关文献

参考文献8

二级参考文献72

  • 1周玉杰,贾德安.批阅三载 增删十次——《冠状动脉粥样硬化性心脏病诊断标准》诞生记[J].中国卫生标准管理,2010,1(4):20-21. 被引量:37
  • 2祁振宇,黄劭敏,邓小武.放疗计划CT值的校准检测及其影响因素分析[J].癌症,2006,25(1):110-114. 被引量:53
  • 3翁学军.蒙特卡罗剂量计算方法的研究[D].南京:东南大学,2003:60-67.
  • 4Schonfeld S J, Lee C, Berrington de Gonz tlez A. Medical exposure to radiation and thyroid cancer. Clin Oncol (R Coil Radiol ) , 201l ,23:244-250.
  • 5Kang EJ, Lee KN, Kim DW, et al. Triple rule-out acute chest pain evaluation using a 320-row-detector volume CT: a comparison of the wide-volume and helical modes. Int J Cardiovasc Imaging, 2012, 28 Suppl 1:7-13.
  • 6Sorantin E, Riccabona M, Stticklschweiger G, et al. Experience with volumetric (320 rows) pediatric CT. Eur J Radiol, 2012,In press. de Hoop B, De Boo DW, Gietema HA, et al. Computer-aided detection of lung cancer on chest radiographs: effect on observer performance. Radiology, 2010,257:532-540.
  • 7Choromafiska A, Macura KJ. Evaluation of solitary pulmonary nodule detected during computed tomography examination. Pol J Radiol, 2012,77:22-34.
  • 8Ruano-Ravina A, Prrez R os M, Femr.ndez-Villar A. Lung cancer screening with low-dose computed tomography after the national lung screening trial: the debate is still open. Arch Bronconeumol, 2013,49 : 158-165.
  • 9Hara AK, Paden RG, Silva AC, et al. Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. A JR Am J Roentgenol,2009,193:764-771.
  • 10Bulla S, Blanke P, Hassepass F, et al. Reducing the radiation dose for low-dose CT of the paranasal sinuses using iterative reconstruction: feasibility and image quality. EurJ Radiol, 2012, 81:2246-2250.

共引文献89