摘要 传统高锰酸盐指数水质自动分析仪在长期运行中,可能由于试剂失效、器件异常等原因导致分析仪测试结果可信度难以评判等问题。该文设计了一种可对仪器运行质量评价的高锰酸盐指数自动分析仪,介绍了分析仪测量原理、系统设计及质控设计方法,并通过实验验证了分析仪的性能和质控评价结果。实验表明,分析仪测量重复性良好,标液核查质控和加标回收质控测试结果可信度高,可较好的实现高锰酸盐指数的监测和分析仪运行质量控制评价,具有较好的应用和推广价值。 The reliability of the traditional CODMn analyzer is difficult to evaluate due to the failure of reagents and abnormal devices.A new CODMn analyzer with the function of operation quality control(QC)is designed,The measuring principle,system design,and quality control design method of the analyzer are introduced.The experiments show that the analyzer has good repeatability,high reliability of quality control results of standard liquid verification and recovery,which can better monitoring of permanganate index and quality control of analyzer operation,which has good application and promotion value.
作者 罗勇钢 卢欣春 孙颖奇 雷丽江 刘冠军 祁文科 LUO Yonggang;LU Xinchun;SUN Yingqi;LEI Lijiang;LIU Guanjun;QI Wenke(NARI Group Corporation(State Grid Electric Power Research Institute),Jiangsu Nanjing 211100,China)
出处 《工业仪表与自动化装置》 2020年第6期24-28,共5页 Industrial Instrumentation & Automation
基金 南京南瑞水利水电科技有限公司科技项目“河道型系列一体化水质分析仪研制”(SLSD19011N)。
关键词 高锰酸盐指数 自动分析仪 水环境质量 质量控制 CODMn automatic analyzer water quality quality control