期刊文献+

化工传热综合实验装置的改进 被引量:3

Improvement of comprehensive experimental device of heat-exchange in chemical engineering
下载PDF
导出
摘要 对引进的化工传热综合实验装置存在的问题进行了分析与改造,通过校准空气流量,排出不凝性气体,改造铂电阻温度计的放置位置,优化了实验装置。结果表明:校准后的空气流量更加准确,实验测得的套管传热准数关联式中的系数A和指数m与教材中理论值的误差减小,并且实验操作的步骤也更加简捷,实验装置的使用寿命也大幅提高。 The problems of the introduced chemical engineering principle experimental device are analyzed.The experimental device is optimized through standardizing the air flowrate value from rotameter,eliminating non-condensable gas and changing the position of the platinum resistance thermometer.The experiment results show that the calibrated air flow value is more accurate,the error of the calculated A and m values is reduced,and the experimental procedure is more convenient,the service life of the device is longer.
作者 应惠娟 俞云良 姬登祥 黄雪雷 YING Huijuan;YU Yunliang;JI Dengxiang;HUANG Xuelei(National Demonstration Center for Experimental Chemistry and Chemical Engineering Education,Zhejiang University of Technology,Hangzhou 310014,China;National Virtual Simulation Experimental Teaching of Chemistry and Chemical Engineering,Zhejiang University of Technology,Hangzhou 310014,China;Chemical Engineering College,Zhejiang University of Technology,Hangzhou 310014,China)
出处 《实验技术与管理》 CAS 北大核心 2020年第10期116-120,共5页 Experimental Technology and Management
基金 浙江省高等教育课堂教学改革项目(kg20160053) 浙江工业大学教学改革项目(Kg201803) 浙江工业大学创新性实验项目(201809)。
关键词 化工 传热 实验装置 改进 chemical engineering heat-exchange experimental device improvement