摘要
通过对45个实际生产的单级双吸清水离心泵的双吸密封间隙由0.3~0.8 mm减小为0.2~0.6 mm的对比性能试验,泵效率提高1.6%~2%,对量大面广使用的单级双吸清水离心泵节能降耗巨大,社会经济效益显著。
the efficiency of the pump was increased by 1.6%to 2%by comparing the sealing gap of 45 single-stage double-suction water centrifugal pumps,which were reduced from 0.3 to 0.8 mm to 0.2 to 0.6 mm.The energy saving and consumption reduction of single-stage double-suction water centrifugal pump with large amount and wide use are huge,and the social and economic benefits are remarkable.
作者
张元华
贾炼
刘莉莉
王禹森
李小宇
ZHANG Yuan-hua;JIA Lian;LIU Li-li;WANG Yu-sen;LI Xiao-yu(Dazhou Agricultural Machinery Research and Promotion Station,Dazhou 635099,China)
出处
《液压气动与密封》
2020年第12期81-82,88,共3页
Hydraulics Pneumatics & Seals
关键词
离心泵
双吸密封环间隙
改进
节能
centrifugal pump
double suction seal ring clearance
improvement
energy saving