摘要 本文描述了田湾核电站俄供发电机定子端部引线的缺陷,分析认为该缺陷的根本原因在于其端部设计不合理,端部引线出现共振,从而导致引线产生疲劳裂纹。为在机组运行期间缓解引线振动,分析发电机定子端部振动大的部位和工艺参数(定冷水温度、热氢温度、无功功率)之间的关系,制定程序进行了相关试验,描述了试验过程,总结了端部引线振动和定子冷却水温度、热氢温度、无功功率间的关系。 The defects of Russian generator stator end wire of Tianwan nuclear power plant is described,and the root causes of the defects is that its design is not reasonable,and resonance appears on the end wire which leads excessive vibration and fatigue crack.To alleviate the stator end wire vibration during operation in the unit,relationship between parts of the big vibration in generator stator and process parameters(stator cooling water temperature,thermal hydrogen temperature,reactive power)are analyzed.Tests are carried out according to complied procedures.The test process are described,and the relationship between end wire vibration and stator cooling water temperature,thermal hydrogen temperature,reactive power are summarized.
作者 周正平 ZHOU Zheng-ping(Jiangsu Nuclear Power Corporation,CNNP,Lianyungan,Jiangsu Prov.222042,China)
出处 《中国核电》 2020年第5期640-643,共4页 China Nuclear Power
关键词 发电机 端部引线 振动缓解 共振 generator end wire vibration ease resonance
  • 相关文献

参考文献3

二级参考文献18

  • 1嵇安森.发电机定子绕组端部振动静态特性的试验研究[J].电力设备,2004,5(9):38-40. 被引量:6
  • 2杨楚明,周尚礼,张启文.汽轮发电机定子绕组端部振动在线监测系统的研制与应用[J].大电机技术,2005(1):23-26. 被引量:4
  • 3王志新,姚大坤.汽轮发电机定子绕组端部振动事故的预防[J].大电机技术,2005(2):21-23. 被引量:4
  • 4汽轮发电机振动[M].北京:中国电力出版社,2000.
  • 5GB/T20140--2006透平型发电机定子绕组端部动态特性和振动试验方法及评定[s],2006.
  • 6KHANG K M, BUCKLEYGW, BROOKS N. Calculation of forces and stresses on generator end-windings 1 Forces IJI- IEEE Trans on Energy Conversion, 1989, 4(4): 661-671.
  • 7AKSTOM Power series Suizhong #2 repair solutions for the eracked flux shie|d [R]. 2014.
  • 8东北电力科学研究院有限公司.绥中发电厂1跨发电机进相运行试验报告[R].沈阳:东北电力科学研究院有限公司,2009.
  • 9OLIVER J, MICHALEC J, ZIMMERLI B, et td. Cnerator winding design-Amos 3 with 25 years experience IJ]. IEEE Trans on Energy Conversion, 2001, 16(1): 87-91.
  • 10东北电力科学研究院有限公司.绥中发电厂1号发电机温升试验报告[R].沈阳:东北电力科学研究院有限公司,2009.