摘要
本文对不同形式瓶塞穿刺器的穿刺力、拔出力研究,对不同形式瓶塞穿刺器进行对比分析,结合安全风险、穿刺力等方面,给出瓶塞穿刺器的最优结构形式。通过本文的数据分析,旨在为产品研发带来准确、科学、客观的试验数据。
In this paper,the puncture force and pull-out force of different types of closure-piercing devices were studied,and the different types of closure-piercing devices were compared and analyzed.Combined with safety risks,puncture force and other aspects,the optimal structural form of bottle stopper piercers was given.Through the data analysis in this paper,the aim was to bring accurate,scientific and objective test data for product research and development.