水样经HLB小柱富集、净化后,采用高效液相色谱-四极杆-高分辨飞行时间质谱同时测定水样中MC-LA、MC-LF、MC-LR、MC-LW、MC-LY、MC-RR、MC-YR、MC-WR等8种微囊藻毒素。试验表明,8种微囊藻毒素在0.500μg/L^100μg/L范围内线性良好,方法检出限为0.001μg/L^0.005μg/L,自来水空白样品3个质量浓度水平的加标回收率为72.5%~99.8%,5次测定结果的RSD为1.9%~11.2%。将该方法用于测定珠海本地水产养殖鱼塘和小型水库的水样,结果均未检出。
8 kinds of microcystin,MC-LA,MC-LF,MC-LR,MC-LW,MC-LY,MC-RR,MC-YR and MC-WR,in water were purified and enriched by HLB column and determined simultaneously by high performance liquid chromatography-quadrupole-high resolution time of flight mass spectrometry(HPLC-Q-TOF).The experimental results showed that the calibration curves of microcystins had good linearity in the range of 0.500μg/L to 100μg/L.The detection limits were between 0.001μg/L and 0.005μg/L.The recoveries of blank samples at three mass concentration levels were from 72.5%to 99.8%,the RSDs of five measurements were from 1.9%to 11.2%.The method was applied in monitoring the water samples from local aquaculture fishponds and small reservoirs in Zhuhai,the results of the 8 kinds of microcystin were not detected.
作者
吴洁珊
倪清泉
任永霞
徐日文
梁宁
黄晶
戴正惠
WU Jie-shan;NI Qing-quan;REN Yong-xia;XU Ri-wen;LIANG Ning;HUANG Jing;DAI Zheng-hui(Gongbei Customs,Zhuhai,Guangdong 519015,China;Zhuhai Productivity Promotion Center,Zhuhai,Guangdong 519015,China)
出处
《环境监测管理与技术》
CSCD
2020年第6期54-57,共4页
The Administration and Technique of Environmental Monitoring
基金
拱北海关科技计划基金资助项目(ZH2017-36)。
关键词
微囊藻毒素
固相萃取
高效液相色谱法
高分辨飞行时间质谱法
水质
Microcystin
Solid phase extraction
High performance liquid chromatography
High resolution time of flight mass spectrometry
Water quality