摘要
详细介绍了低压复合环境试验舱在操作演练中遇到的高度无法调节故障,从试验舱结构布局和连接线路入手,针对故障现象进行了仔细分析与排查,从根本上排除了故障,为相关人员维修类似设备提供了参考。
One fault in altitude regulation was introduced in detail for the low-pressure compound environmental test chamber during operation drill,which was analyzed from the chamber layout and connecting lines and then eliminated completely.References were provided for the maintenance personnel to repair similar devices.
作者
李晗
杨立军
顾昭
王桂友
涂磊
LI Han;YANG Li-jun;GU Zhao;WANG Gui-you;TU Lei(Air Force Characteristic Medical Center,Beijing 100142,China;Guizhou Fenglei Aviation Ordnance Co.,Ltd.,Anshun 561000,Guizhou Province,China)
出处
《医疗卫生装备》
CAS
2020年第12期105-106,共2页
Chinese Medical Equipment Journal
关键词
低压复合环境试验舱
故障分析
故障维修
low-pressure compound environmental test chamber
fault analysis
fault treatment