摘要
根据南京地铁某软土地层地铁车站盾构接收井混凝土套箱发生突涌水险情的现场调查资料,分析了险情事件发生的原因,采用了套箱加固、地面注浆、环境监控、洞内注浆、管片加固等综合治理措施,解决了盾构接收井混凝土套箱突涌水险情,取得了良好的治理效果。
The causes of the water inrush are analyzed according to the field investigation data of the water inrush in the concrete box of shield receiving well of a soft ground subway station in Nanjing.The comprehensive treatment measures such as casing reinforcement,ground grouting,environmental monitoring,grouting in tunnel and segment reinforcement have been adopted to solve the water risk of concrete casing surge in shield receiving well,with good treatment effect.
作者
李俊
LI Jun(China Railway Erju 5th Engineering Co.,Ltd.,Chengdu 610091,China)
出处
《路基工程》
2020年第6期77-85,共9页
Subgrade Engineering
关键词
软土地层
地铁
盾构接收
突涌水
治理研究
soft soil layer
metro
shield receiving
water inrush
control research