摘要
本文主要介绍了中压直流综合电力系统保护动模试验的研究成果。为了研究中压直流综合电力系统保护策略和综合继电保护装置的保护参数的有效性,必须开展相应试验对保护策略进行验证。本文设计了中压直流综合电力系统保护动模试验方案,提出了保护动模试验方法。试验结果表明,中压直流综合电力系统保护动模试验可有效验证保护策略及综合继电保护装置的保护参数。
In order to study the effectiveness of protection strategy in medium-voltage DC integrated power system and protection parameters of integrated relay protection device,it is necessary to verify the protection strategy by experiments.This paper mainly presents the research results of dynamic mode experiments for protection of medium voltage DC integrated power system.Firstly,the scheme of dynamic mode experiments for protection in medium voltage DC integrated power system is designed.Then,the method of dynamic mode experiments for protection is put forward,and the processes of the experiments are introduced.Finally,the experimental results are analyzed.It is concluded that the dynamic mode experiments for protection of medium voltage DC integrated power system can effectively verify the protection strategy and protection parameters of integrated relay protection devices.
作者
严民雄
Yan Minxiong(China Ship Development and Design Center,Wuhan 430064,China)
出处
《船电技术》
2020年第S01期63-66,共4页
Marine Electric & Electronic Engineering
关键词
中压直流综合电力系统
保护动模试验
综合继电保护装置
medium-voltage DC integrated power system
dynamic mode experiment for protection
integrated relay protection device