摘要 根据方舱医院的特点,从暖通专业角度分析负压房间的隔离方法。通过分析热压作用下自然通风对压差控制的影响,得出严格控制方舱医院各功能区的温差是隔绝污染源的重要前提。文中所述观点可供从事传染病医院的设计和建设工作者参考。 According to the characteristics of the cabin hospital,the isolation method of the negative pressure room is analyzed from the perspective of HVAC.By analyzing the influence of natural ventilation on the pressure difference control under the action of heat pressure,it is concluded that strict control of the temperature difference in each functional area of the cabin hospital is an important prerequisite for isolating pollution sources.The opinions can be used as references for those engaged in the design and construction of infectious disease hospitals.
作者 夏锐 王阳 张锦 XIA Rui;WANG Yang;ZHANG Jin(CCCC Wuhan Harbour Engineering Design And Research Co.,Ltd.)
出处 《建筑热能通风空调》 2020年第11期75-77,共3页 Building Energy & Environment
关键词 新型冠状病毒肺炎 方舱医院 压差控制 热压与风压 三区两通道 COVID-19 cabin hospital pressure difference control heat pressure and wind pressure three areas and two channels