期刊文献+

直流微电网改进虚拟直流电机控制策略 被引量:9

DC Microgrid Improved Virtual Direct Current Motor Control Strategy
下载PDF
导出
摘要 针对已有虚拟直流电机(VDCM)控制增大直流母线电压稳态误差的问题,提出一种改进VDCM控制策略。通过分析传统VDCM模型中阻尼系数对母线电压稳态误差及储能变换器控制系统阻尼特性的影响规律,提出一种去掉阻尼系数环节的改进VDCM控制策略。该控制策略既能提高直流变换器的阻尼特性,又能消除阻尼系数对直流母线电压稳态误差的影响,提升直流母线电压的稳定性。仿真和实验结果表明了改进VDCM控制策略的正确性和优越性。 Aiming at the problem that the existing virtual direct current machine(VDCM)control increases the direct current bus voltage steady-state error,an improved VDCM control strategy is proposed.By analyzing the influence of the damping coefficient on the busbar voltage steady-state error and the damping characteristics of the energy storage converter control system in the traditional VDCM model,an improved VDCM control strategy is proposed to remove the damping coefficient.This control strategy can not only improve the damping characteristics of the direct current converter,but also eliminate the influence of the damping coefficient on the direct current bus voltage steady-state error,and improve the stability of the direct current bus voltage.Simulation and experimental results show the correctness and superiority of the improved VDCM control strategy.
作者 支娜 丁有国 赵佳宝 ZHI Na;DING You-guo;ZHAO Jia-bao(Xi'an University of Technology,Xi'an 710048,China)
机构地区 西安理工大学
出处 《电力电子技术》 CSCD 北大核心 2020年第12期93-95,共3页 Power Electronics
基金 国家自然科学基金面上项目(51877175) 陕西省自然基金(2017JM5100)
关键词 直流微电网 虚拟直流电机 阻尼系数 direct current microgrid virtual direct current machine damping coefficient
  • 相关文献

参考文献2

二级参考文献41

  • 1王丹,毛承雄,陆继明.自平衡电子电力变压器[J].中国电机工程学报,2007,27(6):77-83. 被引量:59
  • 2杰里米·里夫金.第三次工业革命[M].张体伟,孙豫宁,译.北京:中信出版社,2012.6.
  • 3毛承雄,王丹.电子电力变压器[M].北京:中国电力出版社,2010.
  • 4Huang A Q, Crow M L, Heydt G T, et al. The future renewable electric energy delivery and management (FREED M)system: The energy interact[J]. Proceedings ofthelEEE, 2011, 99(1): 133-148.
  • 5Snchez-SquellaA, Ortega R, Grifi6R, etal. Dynamic energy router[J]. IEEE Control Systems Magazine, 2010, 30(6): 72-80.
  • 6Bifaretti S, Zanchetta P, Watson A, et al. Advanced power electronic conversion and control system for universal and flexible power management[J]. IEEE Transactions on SmartGrid, 2011, 2(2): 231-243.
  • 7Almaleki M, Wheeler P, Clare J. Sliding mode observer design for universal flexible power management (Uniflex-PM) structure[C]//Proceedings of the 34th Annual Conference of IEEE Industrial Electronics (IECON). Orlando, FL: IEEE, 2008: 3321-3326.
  • 8Zhang J H, Wang WY, Bhattacharya S. Architecture of solid state transformer-based energy router and models of energy traffic[C]//Proceedings of the 2012 IEEE PES Iunovativ Smart Grid Technologies(ISGT). Washington, DC: IEEE, 2012: 1-8.
  • 9Guillod T, Huber J E, Ortiz G, et al. Characterization of the voltage and electric field stresses in multi-cell solid-state transformers[C]//Proceedings of the IEEE Energy Conversion Congress and Exposition. Pittsburgh, PA: IEEE, 2014: 4726-4734.
  • 10Geidl M, Koeppel G, Favre-Perrod P, et al. Energy hubs for the future[J]. IEEE Power & Energy Magazine, 2007, 5(1): 24-30.