摘要
通过对空调制冷量需求的通信机房空间环境和通信机房内设备散热两个方向的分析研究,创新性提出了通信机房空间环境垂直隔断气流方式和通信机房设备板件均衡散热方法,为数据中心机房、传统通信机房乃至基站机房提供了节能环保新技术方面的建议。
Through the analysis and research of the space environment of the communication room and the heat dissipation of the equipment in the communication room with the demand for air conditioning cooling capacity,the vertically partitioning airflow method in communication room space environment and the balanced heat dissipation method of equipment board in communication room is proposed in this paper.It also provides suggestions on new energy-saving and environment-friendly technologies for data center and core computer room,and even base station room.
作者
张礼
王健
王琪
ZHANG Li;WANG Jian;WANG Qi(Anqing Branch of China Mobile Communications Group Anhui Co.,Ltd.,Anqing 246003,China;China Mobile Communications Group Anhui Co.,Ltd.,Hefei 230088,China)
出处
《通信电源技术》
2020年第S01期163-165,170,共4页
Telecom Power Technology
关键词
通信机房
隔断
均衡
communication room
partition
balanced