建立并验证了反相离子对—液质联用法对于辅助降糖胶囊中3种双胍类物质盐酸二甲双胍、盐酸苯乙双胍、盐酸丁二胍进行快速筛查及定性定量检测的方法。以甲醇为样品提取溶剂,超声辅助萃取,选用安捷伦C_(18)(4.6×250 mm,5μm)色谱柱,检测波长235nm,以甲醇—乙酸铵溶液(0.01mol/L)为流动相进行梯度洗脱,流速0.5mL/min,进样量5μL。液相色谱检测后,进入质谱仪进行正离子模式扫描筛查。该分析方法下,加标回收率为87.5%~108.4%,相对标准偏差为0.5%~7.4%,精密度和准确度良好。
A method for rapid screening and qualitative and quantitative determination of three biguanides,MH,PH and BH,in Jiangtang capsules by reversed-phase ion-pair-LC-MS was established and validated.Anagilent technologies C18 column(4.6×250 mm,5μm)was used for the determination at 235 nm.A methanol-B ammonium acetate solution(0.01 mol/L)was used as the mobile phase for gradient elution at a flow rate of 0.5 mL/min.After the HPLC detection,the mass spectrometer for positive ion mode scanning was used for screening.The recovery of standard addition was 87.5%~108.4%,and the relative standard deviation was 0.5%~7.4%,with good precision and accuracy.
作者
安莹
周颖
季剑波
葛冬梅
AN Ying;ZHOU Ying;JI Jian-bo;GE Dong-mei(Xuzhou College of Industrial Technology,Xuzhou,Jiangsu 221140,China;Xuzhou Food and Drug Administration,Xuzhou,Jiangsu 221140,China)
出处
《食品与机械》
北大核心
2020年第12期49-52,共4页
Food and Machinery
基金
江苏省教育厅高校“青蓝工程”扶持基金项目(编号:KC14SM085)。
关键词
降糖
离子对试剂
液质联用
双胍类违禁品
sugar reduction
ion pair reagent
HPLC-MS
biguanide contraband