摘要
卡门涡街现象是引起离心式高压风机出口风道振动的主要原因,严重危害设备的正常运行。对风道卡门涡街现象的形成进行了全面分析,制定了有针对性的应对方案,并加以实施,彻底解决了风道振动对设备正常运行的危害。
Karman vortex street phenomenon is the main cause of vibration in outlet duct of centrifugal high pressure fan,which seriously endangers the normal operation of equipment.This paper comprehensively analyzes the formation of Karman vortex street phenomenon in the air duct,formulates the corresponding countermeasure plan and implements it,and thoroughly removes the harm of air duct vibration to the normal operation of equipment.
作者
范洪武
姚书恒
邢龙飞
井长飞
FAN Hongwu;YAO Shuheng;XING Longfei;JING Changfei(L.uojing Gas Turbine Power Plant,Shanghai Electric Power Co.,Ltd.,Shanghai 200949,China;Shanghai Electric Power Hami Xuanli Gas Power Generation Co.,Ltd.,Hami 839000,Xinjiang Uygur Autonomous Region,China;Shanghai Shangdian Power Engineering Co.,Ltd.,Shanghai 202150,China)
出处
《电力与能源》
2020年第6期767-770,共4页
Power & Energy
关键词
卡门涡街
锅炉
送风机
风道
振动
导流板
Karman vortex street
gas fired boiler
forced draft fan
air duct
vibration
guide plate