期刊文献+

年轻患者全髋关节置换术初期疗效分析 被引量:1

原文传递
导出
摘要 目的探讨年轻患者(年龄≤40岁)全髋关节置换术初期临床疗效。方法回顾性分析自2006-03—2017-05完成的55例年龄≤40岁的初次全髋关节置换术,其中股骨头缺血性坏死37例(双侧21例,共58髋),股骨近端骨折脱位8例(8髋),风湿类疾病5例(5髋),发育性髋关节发育不良并骨性关节炎3例(3髋),股骨近端肿瘤2例(2髋)。结果55例均获得随访,随访时间平均38(24~60)个月。随访期间1例因创伤出现假体周围骨折并松动,2例出现异位骨化,其余患者均未见假体脱位及松动。术后髋关节功能Harris评分较术前明显改善,术后12个月Harris评分平均94.8(78.4~98.5)分,其中优46例,良5例,可4例。结论年轻患者行全髋关节置换术可有限扩大适应证,材料科学、手术技术的进步将为此类患者获得更好的疗效、更长的假体使用寿命提供保障,术中假体类型选择是次要问题,而手术疗效及假体生存率的提高关键在于术者对髋关节疾病病理、解剖熟悉程度以及手术操作的精细程度。
出处 《中国骨与关节损伤杂志》 2020年第12期1270-1272,共3页 Chinese Journal of Bone and Joint Injury
  • 相关文献

参考文献6

二级参考文献83

  • 1Miyanishi K,Hara T,Kaminomachi S,et al.Short-term wear of Japanese highly cross-linked polyethylene in cementless THA.Arch Orthop Trauma Surg,2008,128(9):995-1000.
  • 2Glyn-Jones S,McLardy-Smith P,Gill HS,et al.The creep and wear of highly cross-linked polyethylene:a three-year randomised,controlled trial using radiostereometric analysis.J Bone Joint Surg Br,2008,90(5):556-561.
  • 3Bitsch RG,Loidolt T,Heisel C,et al.Reduction of osteolysis with use of Marathon cross-linked polyethylene.A concise follow-up,at a minimum of five years,of a previous report.J Bone Joint Surg Am,2008,90(7):1487-1491.
  • 4Triclot P,Grosjean G,El Masri F,et al.A comparison of the penetration rate of two polyethylene acetabular liners of different levels of cross-linking.A prospective randomised trial.J Bone Joint Surg Br,2007,89(11):1439-1445.
  • 5Digas G,Karrholm J,Thanner J,et al.5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets:two randomized studies using radiostereometric analysis.Acta Orthop,2007,78(6):746-754.
  • 6Engh CA,Stepniewski AS,Ginn SD,et al.A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked Enduron polyethylene liners.J Arthroplasty,2006,21(6 Suppl 2):17-25.
  • 7Dorr LD,Wan Z,Shahrdar C,et al.Clinical performance of a Durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years.J Bone Joint Surg Am,2005,87(8):1816-1821.
  • 8Bragdon CR,Greene ME,Freiberg AA,et al.Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36-vs 28-mm femoral heads.J Arthroplasty,2007,22(6 Suppl 2):125-129.
  • 9Manning DW,Chiang PP,Martell JM,et al.In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty.J Arthroplasty,2005,20(7):880-886.
  • 10Schmalzried TP,Shepherd EF,Dorey FJ,et al.The John Charnley Award.Wear is a function of use,not time.Clin Orthop Relat Res,2000(381):36-46.

共引文献30

同被引文献1

引证文献1

二级引证文献3

相关作者