摘要
分析某±800 kV换流站换流阀温度相关数据,基于传热模型建立换流阀温度预测函数,准确预测出换流阀温度。
In this paper,relevant data of converter valve temperature in a±800 kV converter station was analyzed.The temperature prediction function of the converter valve was established based on the heat transfer model to accurately predict the temperature of the converter valve.
作者
尹海涛
赖皓
YIN Haitao;LAI Hao(Guangzhou Bureau,CSGEHV Power Transmission Company,Guangzhou 510405,China)
出处
《电工技术》
2020年第23期24-25,共2页
Electric Engineering
关键词
特高压换流站
换流阀
传热模型
预测
UHV converter station
the hyristor valve
the heat-transfer model
predict