相比于传统的地上式污水处理厂,地下式污水处理厂的消防设计有其独有特点。以上海南翔污水处理厂为主要研究对象,通过解读现行消防设计相关规范、分析消防设计边界条件、提炼消防安全影响因素,继而从建筑消防设计、防排烟设计、电气消防设计、消防控制系统设计等方面系统介绍了本工程的消防设计方案,同时结合类似工程案例的共性设计经验,以期为地下式污水处理厂消防设计领域的创新和发展提供有益的借鉴。
Compared with traditional ground wastewater treatment plant,the fire protection design of wastewater treatment plant has some unique characteristics.Taking Shanghai Nanxiang underground wastewater treatment plant as the main research object,this paper systematically introduced the fire protection design scheme of the project from the aspects of building fire protection design,smoke control design,electrical fire protection design and fire control system design by interpreting the current relevant fire protection design specifications,analyzing the boundary conditions of fire protection design and refining the fire safety influencing factors.At the same time,the common design experience of the case was expected to provide useful reference for the innovation and development of fire protection design of underground wastewater treatment plant.
作者
肖艳
Xiao Yan(Shanghai Municipal Engineering Design Institute(Group)Co.,Ltd.,Shanghai 200092,China)
出处
《给水排水》
CSCD
北大核心
2020年第12期30-35,共6页
Water & Wastewater Engineering
基金
上海市科委课题(17DZ2201000,20QB1404800)。
关键词
全地下式污水处理厂
消防设计
构筑物区域
消防分区
Underground wastewater treatment plant
Fire protection design
Structure area
Fire compartment