期刊文献+

霍尼韦尔4000系列扫描架故障案例 被引量:1

A failure case of Honeywell scanner series 4000
下载PDF
导出
摘要 霍尼韦尔的4000型扫描架在很多纸厂都有使用,长时间运行,受环境、备件寿命、维护保养不到位等因素的影响,其稳定性变差,会出现许多故障影响到正常使用。文中介绍了一例给扫描头供电的±15 v开关电源运行不稳定引起的定量和水分频繁且大幅波动的故障案例。通过对此次故障维修经过和总结的描述,分别进行了background测试、reference测试结果对比方法,放射源衰减后定量放大板放大倍数的调整方法,以及类似故障的维修思路和解决方法。 Honeywell 4000 scanner is widely used in many paper mills,but it may cause malfunction when used for a long time if it cannot be maintained regularly.This paper introduced a case of frequent f luctuation of basis weight and moisture content caused by unstable operation of±15 V switching power supply for the scanning head.Based on the description and summary of the fault maintenance process,different tests were conducted,including the background test and reference test results comparison method,the adjustment method of the amplification plate multiple after the attenuation of the radioactive source,and similar fault maintenance thoughts and solutions.
作者 张兴利 马瑞鑫 邵校 赵修欣 Zhang Xingli;Ma Ruixin;Shao Xiao;Zhao Xiuxin(Universal Pulp and Paper(Shandong)Co.,Ltd.,Zaozhuang 277014,Shandong,China)
出处 《中华纸业》 CAS 2021年第2期47-51,共5页 China Pulp & Paper Industry
关键词 4000系列扫描架 定量波动 放射源传感器 开关电源故障 故障案例分析 4000 series scanner basis weight fluctuations radioactive source sensor power on-off failure failure case analysis
  • 相关文献

同被引文献18

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部