期刊文献+

计算机辅助外科手术精度的研究 被引量:3

The Research on Accuracy of Computer-Assisted Surgery
下载PDF
导出
摘要 计算机辅助外科手术系统由立体定位和图像配准两部分组成。整个系统的精度表现为由术前多模医学图像数据重建所得的虚拟空间和术中实际空间的匹配效果的好坏上。系统精度也由定位系统的精度和图像配准的精度组成,而术中的配准精度有依赖于立体定位系统的精度,因此定位的精度是影响整个系统精度的重要因素。最后全面地给出了影响计算机辅助外科手术的可能的误差源。 The computer-assisted surgery system is a complex system. All of the errors can be attributed to the loss of correspondence between the world coordinate system in the operation room and the virtual world coordinate system obtained from the multi-model medical images. The system's accuracy is composed of the accuracy of the localizer and that of registration.In order to improve the system accuracy, we analyse most of the possible error sources. The accuracy of the localizer affects deeply the registration between the intra-operation and pre-operation data.The localizer is the most basic and important part for a computer-assisted surgery system. We give a comprehensive possible error source at the end of the paper.
出处 《中国医疗器械杂志》 CAS 2002年第6期414-417,共4页 Chinese Journal of Medical Instrumentation
基金 中法科技合作项目A类第87号 上海市科学发展基金资助项目(985107016)
关键词 计算机辅助外科手术 手术精度 手术定位 配准 立体定位系统 computer-assisted surgery (CAS), accuracy, localize, registration
  • 相关文献

同被引文献18

  • 1肖德明.计算机辅助骨科导航技术面临的主要问题[J].中华创伤骨科杂志,2005,7(7):617-619. 被引量:21
  • 2田伟,刘亚军,刘波,李勤,胡临,李志宇,袁强.计算机导航在脊柱外科手术应用实验和临床研究[J].中华骨科杂志,2006,26(10):671-675. 被引量:48
  • 3胡益斌.磁导航心血管介入系统的工作原理及其临床应用[J].医疗卫生装备,2006,27(11):64-65. 被引量:8
  • 4Langlotz F,Nolte LP.Technical approaches to computer-assisted or thopedic surgery[J].Eur J Trauma,2004,30(1):1-11.
  • 5Wong KC,Kumta SM,Chiu KH,et al.Precision tumour resection and reconstruction using image-guided computer navigation[J].J Bone Joint Surg Br,2007,89(7):943-947.
  • 6Sikorski JM,Chauhan S.Computer-assisted orthopaedic surgery:do we need CAOS[J].J Bone Joint Surg Br,2003,85(3):319-323.
  • 7Langlotz F.Potential pitfalls of computer aided orthopedic surgery[J].Injury,2004,35 Suppl 1:S-A17-23.
  • 8徐静,陈恳,杨向东,李金泉,朱森强,鲁通,任贺,梁萍.基于超声影像导航的微波消融治疗肝癌机器人系统[J].机器人,2007,29(5):456-462. 被引量:9
  • 9Kuhn M H, Jablonowski M, Gieles P, et al. A unifying framework for accuracy analysis in image-guided surgery[A]. Proceedings of the 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society[C]. Piscataway, NJ, USA: IEEE, 1996. 238-240.
  • 10Li Q H, Zamorano L, Jiang Z W, et al. The influence of different medical image.s on the application accuracy during imageguided surgery[A]. Proceedings of the SPIE (vol.3658) [C]. Bellingham, WA, USA: SPIE, 1999. 232-240.