控制线路是大型游乐设施最重要的电气元件之一,其损坏可能危害乘客的安全。本文通过对一起大型游乐设施事故进行深入分析,阐明了事故原因是控制线路短路引起的抱闸不能打开,从而造成了高空滞留。此外,基于现场勘验和分析,本文还给出了若干对应措施和建议,为相关安全工作提供参考,以提高大型游乐设施的安全性。
The control wire is one of the most important electrical components of large-scale amusement device,and its damage may endanger the safety of passengers.Through an in-depth analysis of a large-scale amusement device accident,this paper explains that the reason of the accident is that the holding brake caused by the short-circuit of the control wire cannot be opened,which results in the high altitude detention.In addition,this paper also gives some corresponding measures and suggestions based on on-site inspection and analysis,providing the reference for relevant security work,so as to improve the safety of large-scale amusement device.
作者
田博
梁朝虎
程海劲
张东阁
Tian Bo;Liang Chaohu;Cheng Haijin;Zhang Dongge(China Special Equipment Inspection and Research Institute,Beijing 100029;Guangdong Institute of Special Equipment Inspection and Research,Foshan 528251)
出处
《中国特种设备安全》
2020年第12期108-111,共4页
China Special Equipment Safety
基金
国家重点研发计划项目“游乐园和景区载人设备全生命周期检测监测与完整性评价技术研究”(2016YFF0203100)
课题1“载人设备质量影响因素分析、风险评价及质量提升对策研究”(2016YFF0203101)支持。
关键词
大型游乐设施
控制线
短路
事故原因分析
Large-scale amusement device
Control wire
Short-circuit
Analysis of the accident cause