期刊文献+

某百万∏型二次再热锅炉再热器壁温偏差调整 被引量:1

Adjustment of Reheater Metal Temperature Imbalances of a 1000MW ∏ Type Secondary Reheat Boiler
下载PDF
导出
摘要 某百万双切圆∏型二次再热锅炉试运过程中高/低压末级再热器壁温沿炉宽方向存在壁温偏差大的问题,限制两级再热汽温达到设计值。通过烟气再循环喷口反切和燃尽风喷口反切,减小了高/低压末级再热器的壁温偏差,为两级再热汽温达到设计值打下了基础。 There is a problem of big metal temperature imbalances in high/low pressure final reheater during the trial operation of a 1000 MW ∏ type secondary reheat boiler,which limits the reheat steam temperature to reach the design value. The metal temperature imbalances of high/low pressure final reheater is reduced by adjusting the horizontal angle of recirculation flue gas nozzle and sofa nozzle,which lays a foundation for high/low pressure reheat steam temperature to reach the design value.
作者 董亮 郭森 郭拯 DONG Liang;GUO Sen;GUO Zheng(State Key Laboratory of Efficient and Clean Coal-fired Utility Boilers(Harbin Boiler Company Limited),Harbin 150046,China)
出处 《锅炉制造》 2021年第1期1-4,共4页 Boiler Manufacturing
关键词 百万∏型二次再热锅炉 再循环喷口反切 燃尽风喷口反切 再热器壁温偏差 a 1000MW ∏ type secondary reheat boiler adjusting the horizontal angle of recirculation flue gas nozzle adjusting the horizontal angle of sofa nozzle reheater metal temperature imbalances