摘要 针对岩滩水电站4号发电机组一直存在的上导摆度和上机架水平振动超规范允许值问题,对该机组进行了变转速和变励磁工况下的振摆检测,采用渐进式动平衡综合分析处理方法,分析计算转子不平衡质量的数值和方位,据此在转子支架上安装配重块,成功解决了转子动不平衡引起的上导摆度和上机架振动幅值大的问题,使得该机组振摆幅值符合标准规范要求。 In view of the problems that the upper deflection and the upper frame horizontal vibration of unit#4 of Yantan Hydropower Station always exceed the allowable values,the unit has been tested for the vibration at variable speed and excitation conditions.The value and orientation of rotor unbalanced mass are analyzed and calculated by progressive dynamic balance comprehensive analysis and treatment method.By installing counterweight on the rotor support,the problems of large amplitude of upper guide and upper frame vibration caused by rotor dynamic imbalance are successfully solved,which makes the unit vibration amplitude meet the requirements of standard specifications.
作者 卢伟 LU Wei(Datang Hydropower Research Institute,Nanning 53000,China)
出处 《云南水力发电》 2021年第1期160-165,共6页 Yunnan Water Power
关键词 水电站 机组转予 动平衡 配重 Hydropower Station Unit Rotor dynamic balance counterweight
  • 相关文献

参考文献5

二级参考文献9

  • 1盛国林,周厚全.水轮发电机组振动分析及转子动平衡试验[J].水利电力机械,2004,26(5):9-10. 被引量:9
  • 2东北水利水电学校.水轮机[M].北京:电力工业出版社,1992.
  • 3陈建农,方勇耕.水轮机及辅助设备运行与维修[M].南京:河海大学出版社,2001.
  • 4于兰阶.水轮发电机组的安装与检修[M].北京:水利电力出版社,2003.
  • 5刘晓亭.大型水轮发电机组稳定性分析及故障诊断[C].2001年国际亚太振动会议论文集.杭州:科学技术出版社,2001.
  • 6刘晓亭,冯辅周.基于水电机组运行工况监测的故障诊断[c].第一届水力发电技术国际会议论文集.北京:中国电力出版社,2006.
  • 7王水华,水力机组测试是技术[M],电力工业出版社计,1983.
  • 8李启章.大型水轮发电机组的振动稳定性问题[J].湖北电力,2001,25(4):21-23. 被引量:9
  • 9方有成,张瑞.水轮发电机组转动不平衡的配重处理[J].西北电力技术,2003,31(5):38-39. 被引量:1

共引文献44

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部