期刊文献+

Comparative study on artificial intelligence systems for detecting early esophageal squamous cell carcinoma between narrow-band and white-light imaging 被引量:8

下载PDF
导出
摘要 BACKGROUND Non-magnifying endoscopy with narrow-band imaging(NM-NBI)has been frequently used in routine screening of esophagus squamous cell carcinoma(ESCC).The performance of NBI for screening of early ESCC is,however,significantly affected by operator experience.Artificial intelligence may be a unique approach to compensate for the lack of operator experience.AIM To construct a computer-aided detection(CAD)system for application in NMNBI to identify early ESCC and to compare it with our previously reported CAD system with endoscopic white-light imaging(WLI).METHODS A total of 2167 abnormal NM-NBI images of early ESCC and 2568 normal images were collected from three institutions(Zhongshan Hospital of Fudan University,Xuhui Hospital,and Kiang Wu Hospital)as the training dataset,and 316 pairs of images,each pair including images obtained by WLI and NBI(same part),were collected for validation.Twenty endoscopists participated in this study to review the validation images with or without the assistance of the CAD systems.The diagnostic results of the two CAD systems and improvement in diagnostic efficacy of endoscopists were compared in terms of sensitivity,specificity,accuracy,positive predictive value,and negative predictive value.RESULTS The area under receiver operating characteristic curve for CAD-NBI was 0.9761.For the validation dataset,the sensitivity,specificity,accuracy,positive predictive value,and negative predictive value of CAD-NBI were 91.0%,96.7%,94.3%,95.3%,and 93.6%,respectively,while those of CAD-WLI were 98.5%,83.1%,89.5%,80.8%,and 98.7%,respectively.CAD-NBI showed superior accuracy and specificity than CAD-WLI(P=0.028 and P≤0.001,respectively),while CAD-WLI had higher sensitivity than CAD-NBI(P=0.006).By using both CAD-WLI and CAD-NBI,the endoscopists could improve their diagnostic efficacy to the highest level,with accuracy,sensitivity,and specificity of 94.9%,92.4%,and 96.7%,respectively.CONCLUSION The CAD-NBI system for screening early ESCC has higher accuracy and specificity than CAD-WLI.Endoscopists can achieve the best diagnostic efficacy using both CAD-WLI and CAD-NBI.
出处 《World Journal of Gastroenterology》 SCIE CAS 2021年第3期281-293,共13页 世界胃肠病学杂志(英文版)
基金 Supported by National Key R&D Program of China,No.2018YFC1315000,No.2018YFC1315005,No.2019YFC1315800,and No.2019YFC1315802 National Natural Science Foundation of China,No.81861168036 and No.81702305 Science and Technology Commission Foundation of Shanghai Municipality,No.19411951600,and No.19411951601 Macao SAR Science and Technology Development Foundation,No.0023/2018/AFJ Dawn Program of Shanghai Education Commission,No.18SG08.
  • 相关文献

同被引文献80

引证文献8

二级引证文献93

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部