期刊文献+

一种标准铂电阻温度计自动检定系统的研制 被引量:2

Development of an Automatic Verification System forStandard Platinum Resistance Thermometer
原文传递
导出
摘要 标准铂电阻温度计的检定过程繁琐、计算量大,迫切需要对其检定系统进行升级。研发电子转换开关以实现标准铂电阻温度计的电子转换,开发自动检定软件以实现自动采集数据、自动计算数据及生成证书内页的功能。系统有效地提升了检定效率,减少了计算量及计算过程的差错率,降低了人力投入。 The verification of standard platinum resistance thermometers is cumbersome and computationally intensive,and there is an urgent need to upgrade its verification system.This paper introduced an electronic transfer switch to achieve the electronic conversion of the standard platinum resistance thermometer,developed an automatic verification software to achieve automatic data collection,calculation,and certificate page generation.The system effectively enhances the verification efficiency,reduces the computation amount and the error rate in the calculation process,and reduces manpower input.
作者 崔馨元 刘亚兵 CUI Xinyuan;LIU Yabing(Henan Institute of Metrology,Zhengzhou 450000)
出处 《计量科学与技术》 2020年第11期29-32,共4页 Metrology Science and Technology
基金 河南省市场监督管理局项目(2018zj13)。
关键词 标准铂电阻温度计 自动检定 软件系统 检定效率 standard platinum resistance thermometer automatic verification software system verification efficiency
  • 相关文献

参考文献10

二级参考文献26

  • 1刘大木.水三相点温度的获得及标准铂电阻温度计R_(tp)的测定[J].上海计量测试,2006,33(4):27-29. 被引量:2
  • 2刘建庆,张金涛,王玉兰,李晓苇.水三相点处铂电阻温度计稳定时间的研究[J].计量技术,2006(9):43-45. 被引量:3
  • 3TJ奎恩.温度测量[M].中国计量出版社,1986..
  • 4JJG160-2007《标准铂电阻温度计检定规程》中华人民共和国国家计量检定规程.2007.06.14.
  • 5JJF1178-2007《用于标准铂电阻温度计的固定点装置校准规范》中华人民共和国国家计量技术规范.2007.06.14.
  • 6JJG160-2007标准铂电阻温度计.中国计量出版社,2007.
  • 7JJF1178--2007用于标准铂电阻温度计的固定点装置.中国计量出版社,2007.
  • 8国家技术监督局计量司.1990国际温标宣贯手册.中国计量出版社,1990.
  • 9Xumo L. Producing the Highest Accuracy from SPRTs[J].Measurements & Control,1996,118-120.
  • 10Preston-Thomas H.The International Temperature Scale of 1990 (ITS-90)[J].Metrologia,1990,27:3-10.