期刊文献+

短寿命核素气溶胶监测相关问题探讨 被引量:4

Discussion on short-lived radionuclide aerosol monitoring
下载PDF
导出
摘要 目前的放射性气溶胶连续监测仪或连续空气监测仪,都是针对长寿命的α放射性核素(如U,Pu)或β放射性核素(如137 Cs,90 Sr),因而在采样测量过程中都不考虑被监测核素的衰变修正。但是,包括核电站在内的具有反应堆运行的核设施,对某些短寿命放射性核素(如88 Rb,138 Cs以及18 F等)的气溶胶监测也是重要的。本文针对短寿命核素气溶胶监测中的有关问题进行讨论,提出了相关的可供监测仪器报告监测结果的实际可行的数据处理方法。 Continuous radioactive aerosol monitors,or continuous air monitors(CAMs)are referred usually to the long-livedα/βnuclides(such as U,Pu and 137 Cs etc).Thus it has not considered the decay corrections of radioactive nuclides themselves during sampling and measuring.But it is important as well to monitor short-lived nuclides(such as 88 Rb,138 Cs and 18 F,etc)in many nuclear factories including nuclear power plants where the nuclear reactors are to be operated.Therefore,the monitoring of short-lived nuclides is important.This paper discusses the problems about the monitoring of short-lived nuclides,and suggests the data processing methods that can be used for the real monitors to obtain reasonable monitoring results of short-lived nuclides.
作者 孟丹 马弢 李建伟 张富国 畅翔 杨屹 杨柳 马英豪 MENG Dan;MA Tao;LI Jianwei;ZHANG Fuguo;CHANG Xiang;YANG Yi;YANG Liu;MA Yinghao(China Institute for radiation protection,Taiyuan 030006)
出处 《辐射防护》 CAS CSCD 北大核心 2020年第6期565-570,共6页 Radiation Protection
关键词 短寿命核素 监测仪 衰变修正 数学推导 short-lived nuclides monitor decay corrections math derivations
  • 相关文献

同被引文献28

引证文献4

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部