摘要 目的:通过对半开放式猴负压隔离器的性能检测与现存问题的探讨,掌握其性能现状,以确保动物生物安全四级实验室的防护水平。方法:根据GB 14925-2010《实验动物环境及设施》及RB199-2015《实验室设备生物安全性能评价技术规范》,对半开放式猴负压隔离器的洁净度、换气次数、动物照度、氨浓度、噪声、工作窗口气流流向、过滤器检漏、压差等进行性能检测。对常见问题进行了分析并提出合理化建议。结果:4个检测项目全部符合技术要求,性能符合国家标准。对照度、风机、一体式拼接尺寸及笼具清洗等问题提出建议及改造方案。结论:确保半开放式猴负压隔离器处于良好的运转状态,并对我国生物安全实验室半开放式猴负压隔离器建造及改造提出了借鉴和指导,为我国发布半开放式猴负压隔离器相关标准的实施提供参考依据。 Objective:To ensure the protection level of high level bio-safety laboratory by exploring the performance testing and existing problems of semi-open negative pressure monkey isolator.Methods:According to GB 14925-2010"Environment and facilities for laboratory animals"and RB199-2015"Technical code for evaluating bio-safety Performance of laboratory equipment",Cleanliness,ventilation times,animal illumination,ammonia concentration,noise,flow direction in working window,filter leak detection,differential pressure for performance testing.Analyze common problems and make rational recommendations.Results:All the four test items met the technical requirements and the performance was qualified.Make Suggestions and improvement plans for the illumination,the fan,the integral splicing size and the cage cleaning.Conclusion:To ensure the good operation of the Semi-open Negative-pressure Monkey Isolator,and to provide reference and guidance for the construction and transformation of the Semi-open Negative-pressure Monkey Isolator in China's bio-safety laboratory,and provide reference for the implementation of the relevant standards for the release of Semi-open Negative-pressure Monkey Isolator in China.
作者 王栋 张兆军 陈爱宇 张珂智 佟海龙 孙百明 石星明 常宗涌 鲍昀利 Wang Dong;Zhang Zhaojun;Chen Aiyu;Zhang Kezhi;Tong Hailong;Sun Baiming;Shi Xingming;Chang Zongyong;Bao Yunli
出处 《洁净与空调技术》 2020年第4期115-119,共5页 Contamination Control & Air-Conditioning Technology
基金 BSL-4实验室关键设备性能及风险评估与发展战略研究(2018YFC1200305)。
关键词 动物生物安全四级实验室 猴负压隔离器 性能检测 现存问题 Animal Biosafety Level 4 Laboratory Negative-pressure Monkey Isolator Performance test Existing problems
  • 相关文献

参考文献4

二级参考文献33

共引文献23

同被引文献9

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部