期刊文献+

电除尘器接地故障处理方法探讨 被引量:2

Discussion on the Treatment Method of Electrostatic Precipitator Grounding Fault
下载PDF
导出
摘要 阐述电除尘工作原理,对电除尘螺旋线断线原因、电除尘器本体故障进行分析,提出在运行中处理电除尘螺旋线断线引起电场故障的方法(电流烧蚀法和电弧烧蚀法),将这两种方法配合使用,能及时消除电除尘器接地故障的隐患,起到稳定生产的作用。 This paper expounds the working principle of electrostatic precipitator, analyzes the reasons for the broken wire of electrostatic precipitator and the internal fault of electrostatic precipitator, and puts forward the methods to deal with the electric field fault caused by the broken wire of electrostatic precipitator in operation(current ablation method and arc ablation method). By using these two methods combined, the hidden trouble of grounding fault of electrostatic precipitator can be eliminated in time, to ensure stable production.
作者 潘武平 谢续文 高诚 PAN Wuping;XIE Xuwen;GAO Cheng(Energy and Power Plant of Taiyuan Iron and Steel(Group)Co.,Ltd.,Taiyuan,Shanxi 030003,China)
出处 《冶金动力》 2021年第1期9-11,共3页 Metallurgical Power
关键词 电除尘 螺旋线 硅整流变 电容器 electrostatic precipitator helix silicon rheometer capacitor