从实验设备、实验方法和测试项目上对比了室内空气净化涂料的不同空气净化性能标准,结果表明,是不同空气净化性能标准之间有较大差异,测试数据对比无法对产品设计提供有效依据。根据涂料空气净化性能标准测试方法现状,探讨了苯及苯系物净化性能的问题,并对现行标准测试方法的优缺点进行比较,提出标准测试方法的不足,为建立更可靠的空气净化涂料标准提供支撑。
This paper compares the different air purification performance standards of indoor air purification coatings from experimental equipment, experimental methods, and test items. The result is that there are great differences among different air purification performance standards, and the comparison of experimental data cannot provide an effective basis for product design. According to the current situation of air purification coatings standard test methods, the problem of the purification performance of benzene and benzene series is discussed, the advantages and disadvantages of the current standard test methods are compared, and the deficiencies of the standard test methods are proposed to establish a more reliable air purification coatings standard.
作者
许巍
唐磊
顾剑勇
叶楠
XU Wei;TANG Lei;GU Jian-yong;YE Nan(Nippon Paint China Co.,Ltd.,Shanghai 201201,China)
出处
《中国涂料》
CAS
2020年第11期11-16,共6页
China Coatings
关键词
净化甲醛
净化甲苯
空气净化
标准
purifying formaldehyde
purifying toluene
air purification
standard