摘要
鉴于目前全国各大发电企业节水减排出现的结垢和环保经济问题,针对某电厂在全年实时控水减排下出现的问题及后续为保证机组安全运行而导致的新鲜水取水超标情况进行探究,详细核算全厂用水情况,并对症分析,给出后续安全运行基础上的节水减排策略。
Based on the scaling and environmental economic problems of water-saving and emission reduction of major power generation enterprises in China,the problems occurred in a power plant under real-time water control and emission reduction in the whole year and the situation of exceeding the standard of fresh water intake caused by the subsequent safe operation of the unit were studied in detail.Water consumption of the whole plant was calculated in detail,and symptomatic analysis was made,and water-saving and emission reduction strategies based on subsequent safe operation were given.
作者
崔仲卿
俞磊
冯杰
CUI Zhongqing;YU lei;FENG Jie(Chnenergy Bengbu Power Generation Co.,Ltd.,Bengbu 233000,China)
出处
《电工技术》
2021年第1期134-135,138,共3页
Electric Engineering
关键词
零排放
结垢
浓缩倍率
循环水
节水
减排
水处理
废水
zero emission
scaling
concentration rate
circulating water
water conservation
emission reduction
water treatment
waste water