摘要
某制药厂废水处理工程,采用微电解/Fenton氧化/水解酸化/生物接触氧化组合工艺处理制药废水,根据实际运行情况分析,该工艺对制药废水有良好的处理效果,耐冲击负荷强、运行稳定,该工程从2016年6月运行至今出水水质达到GB8978-1996《污水综合排放标准》中的三级标准。
In the wastewater treatment project of a pharmaceutical factory,the combined process of microelectrolysis/Fenton oxidation/hydrolytic acidification/biological contact oxidation is used to treat pharmaceutical wastewater.According to the analysis of actual operation,this process has good treatment effect on pharmaceutical wastewater,strong impact load resistance and stable operation.Since the project was operated in June 2016,the effluent quality has reached the standard of integrated wastewater discharge standard(GB8978-1996)Three levels of standards.
作者
代义强
DAI Yiqiang(Fujian Aishan Environmental Protection Technology Co.,Ltd.,Fujian Fuzhou 350000)
出处
《生物化工》
2021年第1期77-80,共4页
Biological Chemical Engineering
关键词
微电解
FENTON氧化
水解酸化
生物接触氧化
制药废水
microelectrolysis
fenton oxidation
hydrolysis acidification
biological contact oxidation
pharmaceutical wastewater