基于自动乳腺超声诊断系统的培训模式的实践 被引量:1

Practice and experience of training model based on automated breast ultrasound system
原文传递
导出
摘要 超声新设备自动乳腺超声(automated breast ultrasound,ABUS)具有扫诊分离、获取的标准化全乳图像可重复阅读的优点,更适用于乳腺超声培训。本研究通过比较以ABUS病例诊断实践为核心的乳腺超声影像培训模式和以手持超声操作与诊断为核心的传统乳腺超声影像培训模式,发现以ABUS病例诊断实践为核心的新培训模式培训周期短、超声医生诊断水平提升快,新培训模式能更高效地培养出更多技术合格的乳腺疾病超声诊断医生。 The new ultrasound device,automated breast ultrasound(ABUS),has the advantages of repeatable reading of standardized whole breast images,and can separate ultrasound scanning and diagnosis.ABUS is more suitable for breast ultrasound training.This study compared the breast ultrasound imaging training model with ABUS diagnosis practice as the core and the traditional breast ultrasound imaging training model with handhold ultrasound operation and diagnosis as the core,and found that the new training model with ABUS diagnosis practice as the core had a short training period.The diagnostic level of doctors have improved rapidly,and the new training model could efficiently train more technically qualified ultrasound doctors for breast disease.
作者 宋宏萍 闫静茹 赵妮 刘丽文 Song Hongping;Yan Jingru;Zhao Ni;Liu Liwen(Department of Ultrasound,The First Affiliated Hospital of Air Force Medical University,Xi'an 710032,China)
出处 《中华医学教育探索杂志》 2021年第2期186-189,共4页 Chinese Journal of Medical Education Research
基金 陕西省高等教育学会2017年度高等教育科学研究项目(XGH17281) 2017年陕西省高等教育教学改革研究项目(17JG004) 陕西省国际科技合作与交流计划(2017KW-057)。
关键词 乳腺 超声医生 继续医学教育 培训模式 Breast Sonographer Continuing medical education Training model
  • 相关文献

参考文献7

二级参考文献41

  • 1周永昌 郭万学.超声医学[M].北京:科学技术文献出版社,1998.1055-1059.
  • 2Athan B.,Cecile GV.,Gael M.,et al.Comparison of the Ef-ficacy of Sonography,Magnetic Resonance Imaging and Con-ventional Radiography for the Detection of Bone Erosions inRheumatoid Arthritis Patients:A Systematic Review and Meta-Analysis[J].Rheumatology,2011,50(6):1137-1147.
  • 3Athan B, Cecile GV, Gael M, et al. Comparison of the efficacy of sonography, magnetic resonance imaging and conventional radiog- raphy for the detection of bone erosions in rheumatoid arthritis patients: A systematic review and meta analysis[J]. Rheumatology, 2011, 50(6): 1137-1147.
  • 4Flobbe K, Nelemans PJ, Kessels AG, et al. The role ofultrasonography as an adjunct to mammography in the detection of breast cancer: a systematic review [J]. Eur ] Cancer, 2002, 38 (8): 1044-1050.
  • 5Chou YH, Tiu CM, Chen J. et al. Automated full-field breast ultrasonography: the past and the present [J] .] Med Ultrasound, 2007,15(1):31-44.
  • 6Wehrle NK, Hellerhoff K, Notohamiprodjo M, et al. Automated breast volume scanner (ABVS): a new approach for breast imaging [J]. Radiologe, 2010, 50 (11): 973-981. DOl: 10.1007/ sOOl17-01 0-2068-8.
  • 7Chang JM, Cha JH, Park JS, et al. Automated breast ultrasound system (ABUS): reproducibility of mass localization, size measurement, and characterization on serial examinations [J] ' Acta Raiol, 2015, 56 (10): 1163-1170. DOl: 10, 1177/ 0284185114551565.
  • 8Tozaki M, Isobe S, Yamaguchi M, et al. Optimal scanning technique to cover the whole breast using an automated breast volume scanner[J] . J pn J Radiol, 2010,28 (4) : 325-328. DOl: 10. 1007/ sI1604-01O-0424-2.
  • 9Brisson AM, Steinmetz P, Oleskevich S, et al. A comparison of telemedicine teaching to in-person teaching for the acquisition of an ultrasound skill-a pilot project[J]. J Telemed Telecare, 2015, 21 (4): 235-239. DOI: 10.1177/1357633X15575446.
  • 10刘政,王冬,高顺记,葛垚,宋鹏飞.远程医疗系统在超声教学中的初步应用[J].临床超声医学杂志,2008,10(5):359-360. 被引量:2

共引文献52

同被引文献12

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部