摘要
目的:分析显微镜检测法+尿沉渣全自动分析仪对尿常规的检验价值。方法:选取2019年2月~2019年6月行尿常规检验的患者1000例,分别实施显微镜检测法和尿沉渣全自动分析仪,对比单一方案和联合方案定量检测结果和细胞检出率。结果:联合方案定量红细胞检出率为92.00%,定量白细胞检出率为94.20%,高于单一方案的40.00%和46.80%,数据差异有意义(P<0.05);联合方案红细胞检出率和白细胞检出率高于单一方案,存在差异(P<0.05)。结论:显微镜检测法和尿沉渣全自动分析仪,可促进红细胞和白细胞检出率的提升。
Objective:To analyze the recommended value of microscopic detection method and urinary sediment automatic analyzer for routine urine test.Methods:1000 patients who underwent routine urine test from February 2019 to June 2019 were selected and the microscopic detection method and urinary sediment automatic analyzer were implemented respectively.The quantitative detection results and cell detection rate of single scheme and combined scheme were compared.Results:The detection rate of quantitative red blood cell and white blood cell was 92.00%and 94.20%respectively,which were higher than 40.00%and 46.80%of single scheme,with data difference(P<0.05);the red blood cell detection rate and white blood cell detection rate of combined scheme were higher than that of single scheme(P<0.05).Conclusion:Microscope detection and urine sediment automatic analyzer can promote the detection rate of red blood cells and white blood cells.
作者
王学菊
WANG Xue-ju(Tianjin Beichen Hospital,Tianjin 300400)
出处
《中国医疗器械信息》
2021年第4期143-145,共3页
China Medical Device Information
关键词
显微镜检测法
尿沉渣
全自动分析仪
尿常规检验
microscopic detection
urinary sediment
automatic analyzer
routine urine test