文章介绍采用压片法制样,X射线荧光光谱法分析石灰石中CaO和SiO_(2),通过自制标准试样,根据产地不同分别建立工作曲线,克服了压片法的基体效应和矿物效应,分析准确度和精密度进一步提高,分析周期短,时效性好。
In this paper,SiO_(2) and CaO in limestone samples prepared using squash method were analyzed on the basis of X-ray fluorescence spectrum.In order to overcome the effects of matrix and mineral,self-made standard samples were prepared and working curves of limestone from difference areas were established.It was shown that the validity and precision of the analysis are improved.Also,the analysis period is timely and shorter.
作者
连喜萍
LIAN Xi-ping(Laboratory Testing Centre of Ben Gang Group Corporation,Benxi Liaoning 117000,China)
出处
《辽宁科技学院学报》
2021年第1期27-29,共3页
Journal of Liaoning Institute of Science and Technology
关键词
X射线荧光光谱法
压片法
石灰石
X-ray fluorescence spectrum
Squash method
Limestone