摘要
随着白内障手术由复明性向屈光性转变,对角膜的散光矫正显得越来越重要。而角膜散光不仅仅应该关注角膜前表面的散光数据,更应该考虑角膜后表面的散光,否则对散光人工晶状体植入矫正角膜散光可能出现不同程度的术后屈光误差。角膜后表面散光均值约为0.37 D,且多数情况下会产生逆规散光的效果,因此在进行散光型人工晶状体计算时应考虑到这一特点,进一步防止术后欠矫或过矫的发生。
With the cataract surgery evolving from visual restoration surgery to refractive surgery,surgical correction of corneal astigmatism becomes more and more important.For Toric intraocular lens implantation,the surgeon should not only pay attention to the values in surface of anterior corneal astigmatism but also that in posterior corneal astigmatism.Otherwise,unwanted postoperative refractive errors may occur.The mean value of posterior corneal astigmatism was around 0.37 D.In most cases,the posterior corneal astigmatism produces against-the-rule effect.Therefore,the above-mentioned feature of posterior corneal astigmatism should be noticed to prevent the under-correction or over-correction effect of toric lens.
作者
董静(综述)
张素华
王晓刚(审校)
DONG Jing;ZHANG Suhua;WANG Xiaogang(Department of Ophthalmology,First Hospital of Shanxi Medical University,Taiyuan 030001;First Department of Cataract,Shanxi Eye Hospital,Taiyuan 030002,China)
出处
《眼科学报》
CAS
2021年第2期167-175,共9页
Eye Science
基金
国家自然科学基金(81971697)。
关键词
角膜
前表面
后表面
散光
人工晶状体
cornea
anterior surface
posterior surface
astigmatism
intraocular lens