介绍了一套固态高分辨率食管测压系统校准装置在医院现场的应用,并对应用过程中出现的一些重点问题进行了实验论证。结果显示:该校准装置可实现固态高分辨率食管测压系统的有效溯源。
This paper mainly introduces the application of calibration device for solid high-resolution esophageal manometry developed by our institute in the hospitall,and some key problems in the application process are discussed and analyzed.The results show that the calibration device can effectively trace the source of solid-state high-resolution esophageal manometry.
作者
秦亭亭
沈淘淘
刘贝贝
Qin Tingting;Shen Taotao;Liu Beibei(Shanghai Institute of Measurement and Testing Technology)
出处
《上海计量测试》
2021年第1期24-26,共3页
Shanghai Measurement and Testing
关键词
固态高分辨率
食管
压力
校准
solid high-resolution
esophagus
pressure
calibration