针对300 MW机组汽轮机通流改造后的特点,利用改造后的滑压运行试验,得出了机组在调峰范围内的汽轮机滑压运行参考曲线,选择合适的阀门开启顺序,对典型运行工况的阀门内部流场进行数值模拟和分析,并对阀门管理方式给出积极建议。
According to the characteristics of the 300 MW steam turbine after the flow path retrofit,and based on the reformed sliding pressure operation tests,the steam turbine sliding pressure operation reference curves were derived in range of peak regulation.The appropriate valve opening sequence was selected,and the internal flow field of the valve under typical operating conditions was numerically simulated and analyzed,and the positive suggestions for valve management were proposed.
作者
胡远涛
张琰
张聪
HU Yuantao;ZHANG Yan;ZHANG Cong(Shanghai Electric power Co.,Ltd.,Shanghai 200010,China;Shanghai Nuclear Engineering Research&Design Institute Co.,Ltd.,Shanghai 200233,China;Shandong Electric Power Engineering Consulting Institute Co.,Ltd.,Jinan 250013,Shangdong Province,China)
出处
《电力与能源》
2021年第1期110-114,133,共6页
Power & Energy
关键词
汽轮机
通流改造
进汽阀
阀门管理
数值模拟
steam turbine
flow path retrofit
inlet valve
valve management
numerical simulation