摘要 经辐照交联ETFE电缆的会对金属产生腐蚀危害,这就需要加热失活技术。经研究发现,随着加热失活温度上升,不同辐照剂量的氟含量呈现逐渐下降的趋势。加热失活技术可以有效减少辐照交联ETFE电缆的氟析出现象,并显著改善因氟析出引起的连接器或其他设备腐蚀情况。 The insulation material of irradiation cross-linked ETFE cables may cause corrosion damage to metal,which requires post-treatment technology.It was found that with the increase of post-treatment temperature,the fluorine content of different irradiation doses decreased gradually.The post-treatment can effectively reduce the appearance of fluorine evolution in irradiated cross-linked ETFE cables,and significantly improve the corrosion of connectors or other equipment caused by fluorine precipitation.
出处 《科技创新与应用》 2021年第11期17-22,共6页 Technology Innovation and Application
关键词 辐照交联 抗腐蚀 加热失活工艺 irradiation cross-linking corrosion resistance post-treatment process.
  • 相关文献

参考文献2

二级参考文献7

  • 1赵祥臻.辐射交联F_(40)航空导线[J].上海工程技术大学学报,1995,9(1):14-18. 被引量:9
  • 2赵祥臻.快速电子辐照F40中含氟自由基在空气中的衰变.放射化学与核化学,1982,4(2):111-111.
  • 3Mohamed Mahmoud Nasefa,Hamdani Saidib,Khairul Zaman M Dahlanc.Electron beam irradiation effects on ethylene tetra fluoro ethylene copolymer films[J].Radiation Physics and Chemistry,2003,68(5):875-883.
  • 4Akihiro Oshima,Shigetoshi Ikeda,Tadao Seguchi,et al.Temperature effect on radiation induced reactions in ethylene and tetrafluoroethylene copolymer(ETFE)[J].Radiat Phys Chem,1997,50(5):519-522.
  • 5忻济民.电线用辐照交联乙烯-四氟乙烯共聚物绝缘料[C]//中国电工技术学会电线电缆专委会、中国电机工程学会电力电缆分专委会2002年年会暨交联电缆专题研讨会.2002.
  • 6邢大立,赵祥臻,王寿泰.快速电子辐照F-40自由基的ESR定量方法[J].东莞理工学院学报,1999,6(1):33-35. 被引量:1
  • 7陈有智.电线电缆质量问题及对策探讨[J].经贸实践,2018(12X):344-344. 被引量:4