期刊文献+

耐张线夹压接质量的相控阵超声检测 被引量:5

Phased array ultrasonic testing of the quality of tension clamp
下载PDF
导出
摘要 结合相控阵超声检测理论与耐张线夹的实际情况,分析了相控阵超声检测应用于输电线路耐张线夹压接质量检测的可行性。结合有限元仿真结果,分别对耐张线夹的3个压接位置进行相控阵超声现场检测,并对其结果进行分析,验证了使用相控阵超声检测输电线路耐张线夹压接质量的可行性。 Based on the theory of ultrasonic phased array detection and the actual situation of the strain clamp,the feasibility of applying the ultrasonic phased array technology to the quality inspection of strain clamp of transmission line has been analyzed.According to the finite element simulation results,three crimping positions of the strain clamps have been tested,and the feasibility of using ultrasonic phased array technology to detect the crimping quality of strain clamps has been verified.
作者 李君华 梁世容 张兴森 LI Junhua;LIANG Shirong;ZHANG Xingsen(Electric Power Research Institute of Guangxi Power Grid Co.,Ltd.,Nanning 530023,China)
出处 《无损检测》 CAS 2020年第12期35-38,51,共5页 Nondestructive Testing
基金 广西电网有限责任公司科技项目(GXKJXM20180285)。
关键词 耐张线夹 有限元仿真 相控阵超声检测 strain clamp the finite element simulation phased array ultrasonic detection
  • 相关文献

参考文献5

二级参考文献57

  • 1OU Jinping, LI Hui. Structural health monitoring in China's Mainland: review and future trends[J]. Struc- tural Health Monitoring, 2010, 9(3): 219-232.
  • 2GUO N, CAWLEY P. The interaction of Lamb waves with delamination in composite laminates[J]. Journal of the Acoustical Society of America, 1993, 94 (4): 2240-2246.
  • 3TOYAMA N, NODA J, SHIBUYA Y, et al. Quick inspection of impact induced delamination in cross-ply laminate by the use of Lamb waves[J]. Journal of Ma- terials Science Letters, 2003, 22(7): 523-525.
  • 4MASSEREY B, FROMME P. On the reflection of coupled Rayleigh-like waves at surface defects in plates[J]. Journal of the Acoustical Society of Ameri- ca, 2008, 123(1): 88-98.
  • 5ROSE J L. A baseline and vision of ultrasonic guided wave inspection potential[J]. Journal of Pressure Ves- sel Technology, 2002, 4(124): 273-282.
  • 6DEGERTEKIN F L, KHURI-YAKUB B T. Lamb wave excitation by Hertzian contacts with application in NDE[J]. IEEE Transactions on Ultrasonics, Fer- roelectrics and Frequency Control, 1997, 44(4): 769- 779.
  • 7SU Z, YE L, BU X. A damage identification tech-nique for CF/EP composite delaminates using distribu- ted piezoelectric transducers [J]. Composite Struc- tures, 2002, 7(57): 465-471.
  • 8GIURGIUTIU V. Tuned Lamb wave excitation and detection with piezoelectric wafer active sensors for structural health monitoring[J]. Journal of Intelligent Material Systems and Structures, 2005, 4(16):291- 305.
  • 9DISCALEA F L, MATT H, BARTOLI I, et al. Health monitoring of UAV wing skin-to-spar joints u- sing guided waves and macro fiber composite trans- ducers[J]. Journal of Intelligent Material Systems and Structures, 2007, 4(18): 373-388.
  • 10LEE B C, STASZEWSKI W J. Lamb wave propaga- tion modelling for damage detection Ⅱ: damage moni- toring strategy[J]. Smart Materials and Structures, 2007, 2(16): 260-274.

共引文献50

同被引文献40

引证文献5

二级引证文献5