期刊文献+

心冲击信号研究进展及其在医学中的应用 被引量:2

Research Progress of Ballistocardiogram Signal and Its Application in Medicine
下载PDF
导出
摘要 心冲击图(Ballistocardiogram,BCG)技术具备无创、非接触式和可长期连续监测等优点。本文在简单介绍BCG技术的基础之上,对BCG信号检测方式及其在生命体征检测、心血管功能参数监测和睡眠结构分析等医学中的应用研究进展做一综述,并对BCG技术难点和存在的问题进行分析和讨论,以期为后续BCG技术相关探索、研究和应用提供一定的思路或指导。 Ballistocardiogram(BCG)has the advantages of noninvasive,noncontact and long-term continuous monitoring.Based on the brief introduction of BCG technology,this paper reviews the research progress of BCG signal detection methods and its application in vital signs detection,cardiovascular function parameter monitoring and sleep structure analysis.The technical difficulties and existing problems of BCG are also discussed,so as to provide some ideas or guidance for the subsequent exploration,research and application of BCG technology.
作者 夏建松 朱文武 杨挺 XIA Jiansong;ZHU Wenwu;YANG Ting(Zhejiang Center for Medical Device Evaluation,Hangzhou Zhejiang 311121,China)
出处 《中国医疗设备》 2021年第3期168-172,共5页 China Medical Devices
关键词 心冲击信号 生命体征检测 心脏功能监测 睡眠结构分析 ballistocardiogram signal vital sign detection cardiac function monitoring sleep structure analysis
  • 相关文献

参考文献2

二级参考文献21

  • 1胡寿盛,孔灵芝.中国心血管病报告2011[R].北京:卫生部心血管病防治中心.2012.
  • 2Postolache O A, Girao P M B S, Mendes J, et al. Physiological parameters measurement based on wheelchair embedded sensors and advanced signal processing [J]. IEEE Transactions on Instrumentation and Measurement, 2010, 59(10) ; 2564- 2574.
  • 3Mack D C, Patrie J T, Suratt P M, et al. Development and preliminary validation of heart rate and breathing ratedetection using a passive, ballistocardiography-based sleep monitoring system [J]. IEEE Transactions on Information Technology in Biomedicine, 2009, 13(1) : 111 - 120.
  • 4Inan O T, Etemadi M, Wiard R M, et al. Robust ballistocardiogram acquisition for home monitoring [J]. Physiological Measurement, 2009, 30(2) : 169 - 185.
  • 5Gonzalez-Landaeta R, Casas O, Pallas-Areny R. Heart rate detection from an electronic weighing scale [J] Physiological Measurement, 2008, 29(8) : 979 - 989.
  • 6Shin J, Hwang S, Chang M, et al. Heart rate variability analysis using a ballistocardiogram during valsalva manoeuvre and post exercise [J]. Physiological Measurement, 2011, 32(8) : 1239 - 1265.
  • 7Etemadi M, Inan O T, Giovangrandi L, et al. Rapid assessment of cardiac contractility on a home bathroom scale [J]. IEEE Transactions on Information Technology in Biomedicine, 2011, 15(6) : 864 - 869.
  • 8Inan OT, Etemadi M, Paloma A, et al. Non-invasive cardiac output trending during exercise recovery on a bathroom-scale-based ballistocardiograph[J]. Physiological Measurement, 2009, 30(3) : 261 - 274.
  • 9苏建伟.基于心冲击的心脏功能检测技术的研究[D].北京清华大学,2010.
  • 10Pan J, Tompkins W J. A real-time QRS detection algorithm [J]. IEEE Transactions on Biomedical Engineering, 1985, 32(3) : 230 - 236.