针对常用离心泵特性曲线拟合算法中出现的驼峰形曲线问题,通过比较多种常用的拟合算法,并分析其优缺点;以山西某泵站离心泵为例,采用非线性最小二乘法拟合水泵特性曲线;最后通过泵站离心泵的实测数据,与最小二乘拟合的结果进行对比分析。结果表明,非线性最小二乘拟合算法精确度可靠,拟合出的离心泵特性曲线符合实测数据的整体趋势,更加合理可靠。研究成果可为泵站运行管理提供参考。
Aiming at the hump-shaped curve in the characteristic curve fitting method of centrifugal pump,this paper compares various fitting methods and analyzes their advantages and disadvantages.Taking the centrifugal pump of a pumping station in Shanxi as an example,the nonlinear least square method is designed to fit the characteristic curve.Finally,the measured data of centrifugal pump in the pumping station are compared with the results of least square fitting.The results show that the nonlinear least square fitting method is accurate and the characteristic curve of the fitted centrifugal pump conforms to the overall trend of the measured data,and is more reasonable and reliable.The research results can provide reference for the operation and management of the pumping station.
作者
杜卓
吴建华
张少华
焦莉雅
孙志勇
辛国伟
DU Zhuo;WU Jian-hua;ZHANG Shao-hua;JIAO Li-ya;SUN Zhi-yong;XIN Guo-wei(College of Hydro Science and Engineering,Taiyuan University of Technology,Taiyuan 030024,China)
出处
《水电能源科学》
北大核心
2021年第3期152-154,共3页
Water Resources and Power
基金
山西省重点研发计划(社会发展领域)项目(201803D31207-1)
山西省水利科学技术研究与推广项目(SZ-2020-06)
山西省高等学校科技成果转化培育项目(2020CG018)。
关键词
离心泵
特性曲线
最小二乘法
非线性
centrifugal pump
characteristic curve
least square method
nonlinearity