摘要
本文从铁路行业最不利水位的概念和主要作用入手,分析了规范中最不利水位定义的局限性,提出了完善最不利水位定义的建议,构建了以最小偏移率确定浸水支挡结构控制项和最不利水位的通用方法。结合具体的工程实例,演示了确定最不利水位的步骤和过程。
This paper analyzes the concept and main functions of the most unfavorable water level in the railway industry,analyzes the limitations of the definition of the most unfavorable water level in the codes,and then puts forward suggestions on improving this definition.It also establishes a general method for determining the control items and the most unfavorable water level of the submerged retaining structure with the minimum offset rate.At last,the paper demonstrates the steps and processes of determining the most unfavorable water level with specific engineering examples.
作者
江靓瑾
张韵
李福华
陈邵勇
丁杨
JIANG Liangjin;ZHANG Yun;LI Fuhua;CHEN Shaoyong;DING Yang(Sichuan Railway Group Co.,Ltd.,Chengdu 610031,China;China Railway No.2 Engineering Group Co.,Ltd.,Chengdu 610031,China;Chengdu Southwest Jiaotong University Design and Research Institute Co.,Ltd.,Chengdu 610031,China)
出处
《高速铁路技术》
2021年第1期1-5,11,共6页
High Speed Railway Technology
关键词
浸水
支挡结构
检算项
不利极值
偏移率
控制项
最不利水位
submerge
retaining structure
check calculation item
unfavorability limit
offset rate
control item
most unfavorable water level